Skip to content

United States · ADA · Accessibility standard

2010 ADA Standards for Accessible Design

The Department of Justice’s scoping and technical accessibility requirements for facilities covered by the ADA.

AccessibilityAnthropometry & ergonomics
Open original PDF at page 178

Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.

TECHNICAL CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES 607.5 Controls. Controls, other than drain stoppers, shall be located on an end wall. Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub. Controls shall comply with 309.4. Figure 607.5 Bathtub Control Location 607.6 Shower Spray Unit and Water. A shower spray unit with a hose 59 inches (1500 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided. The shower spray unit shall have an on/off control with a non-positive shut-off. If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars. Bathtub shower spray units shall deliver water that is 120°F (49°C) maximum. Advisory 607.6 Shower Spray Unit and Water. Ensure that hand-held shower spray units are capable of delivering water pressure substantially equivalent to fixed shower heads. 607.7 Bathtub Enclosures. Enclosures for bathtubs shall not obstruct controls, faucets, shower and spray units or obstruct transfer from wheelchairs onto bathtub seats or into bathtubs. Enclosures on bathtubs shall not have tracks installed on the rim of the open face of the bathtub. 608 Shower Compartments 608.1 General. Shower compartments shall comply with 608. Advisory 608.1 General. Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space. 608.2 Size and Clearances for Shower Compartments. Shower compartments shall have sizes and clearances complying with 608.2. 608.2.1 Transfer Type Shower Compartments. Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915 mm) wide minimum entry on the face of the shower 174 - 2010 Standards: Titles II and III Department of Jus2ti1c1e Titles II and III - 2010 Standards - 145

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.