TECHNICAL CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES
607.5 Controls. Controls, other than drain stoppers, shall be located on an end wall. Controls shall be
between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of
the width of the bathtub. Controls shall comply with 309.4.
Figure 607.5
Bathtub Control Location
607.6 Shower Spray Unit and Water. A shower spray unit with a hose 59 inches (1500 mm) long
minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be
provided. The shower spray unit shall have an on/off control with a non-positive shut-off. If an
adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct
the use of grab bars. Bathtub shower spray units shall deliver water that is 120°F (49°C) maximum.
Advisory 607.6 Shower Spray Unit and Water. Ensure that hand-held shower spray units
are capable of delivering water pressure substantially equivalent to fixed shower heads.
607.7 Bathtub Enclosures. Enclosures for bathtubs shall not obstruct controls, faucets, shower and
spray units or obstruct transfer from wheelchairs onto bathtub seats or into bathtubs. Enclosures on
bathtubs shall not have tracks installed on the rim of the open face of the bathtub.
608 Shower Compartments
608.1 General. Shower compartments shall comply with 608.
Advisory 608.1 General. Shower stalls that are 60 inches (1525 mm) wide and have no
curb may increase the usability of a bathroom because the shower area provides additional
maneuvering space.
608.2 Size and Clearances for Shower Compartments. Shower compartments shall have sizes and
clearances complying with 608.2.
608.2.1 Transfer Type Shower Compartments. Transfer type shower compartments shall be 36
inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of
opposing sides and shall have a 36 inch (915 mm) wide minimum entry on the face of the shower