CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES TECHNICAL compartment. Clearance of 36 inches (915 mm) wide minimum by 48 inches (1220 mm) long minimum measured from the control wall shall be provided. Figure 608.2.1 Transfer Type Shower Compartment Size and Clearance 608.2.2 Standard Roll-In Type Shower Compartments. Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides and shall have a 60 inches (1525 mm) wide minimum entry on the face of the shower compartment. 608.2.2.1 Clearance. A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the controls or, where provided, not on the side of the clearance adjacent to the shower seat. D2e1p2artment of Justice 2010 Standards: Titles II and III - 175 Titles II and III - 2010 Standards - 146

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.