CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES TECHNICAL
608.3 Grab Bars. Grab bars shall comply with 609 and shall be provided in accordance with 608.3.
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height
above the finish floor.
EXCEPTIONS: 1. Grab bars shall not be required to be installed in a shower located in a bathing
facility for a single occupant accessed only through a private office, and not for common use or
public use provided that reinforcement has been installed in walls and located so as to permit the
installation of grab bars complying with 608.3.
2. In residential dwelling units, grab bars shall not be required to be installed in showers located in
bathing facilities provided that reinforcement has been installed in walls and located so as to permit
the installation of grab bars complying with 608.3.
608.3.1 Transfer Type Shower Compartments. In transfer type compartments, grab bars shall be
provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall.
Figure 608.3.1
Grab Bars for Transfer Type Showers
608.3.2 Standard Roll-In Type Shower Compartments. Where a seat is provided in standard roll-
in type shower compartments, grab bars shall be provided on the back wall and the side wall
opposite the seat. Grab bars shall not be provided above the seat. Where a seat is not provided in
standard roll-in type shower compartments, grab bars shall be provided on three walls. Grab bars
shall be installed 6 inches (150 mm) maximum from adjacent walls.
Figure 608.3.2
Grab Bars for Standard Roll-In Type Showers