TECHNICAL CHAPTER 8: SPECIAL ROOMS, SPACES, AND ELEMENTS
809.5.2.1 Activation. All visible alarm appliances provided within the residential dwelling unit for
smoke detection notification shall be activated upon smoke detection.
809.5.3 Interconnection. The same visible alarm appliances shall be permitted to provide
notification of residential dwelling unit smoke detection and building fire alarm activation.
809.5.4 Prohibited Use. Visible alarm appliances used to indicate residential dwelling unit smoke
detection or building fire alarm activation shall not be used for any other purpose within the
residential dwelling unit.
809.5.5 Residential Dwelling Unit Primary Entrance. Communication features shall be provided
at the residential dwelling unit primary entrance complying with 809.5.5.
809.5.5.1 Notification. A hard-wired electric doorbell shall be provided. A button or switch shall
be provided outside the residential dwelling unit primary entrance. Activation of the button or
switch shall initiate an audible tone and visible signal within the residential dwelling unit. Where
visible doorbell signals are located in sleeping areas, they shall have controls to deactivate the
signal.
809.5.5.2 Identification. A means for visually identifying a visitor without opening the residential
dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of
view.
Advisory 809.5.5.2 Identification. In doors, peepholes that include prisms clarify the
image and should offer a wide-angle view of the hallway or exterior for both standing
persons and wheelchair users. Such peepholes can be placed at a standard height and
permit a view from several feet from the door.
809.5.6 Site, Building, or Floor Entrance. Where a system, including a closed-circuit system,
permitting voice communication between a visitor and the occupant of the residential dwelling unit is
provided, the system shall comply with 708.4.
810 Transportation Facilities
810.1 General. Transportation facilities shall comply with 810.
810.2 Bus Boarding and Alighting Areas. Bus boarding and alighting areas shall comply with 810.2.
Advisory 810.2 Bus Boarding and Alighting Areas. At bus stops where a shelter is
provided, the bus stop pad can be located either within or outside of the shelter.
810.2.1 Surface. Bus stop boarding and alighting areas shall have a firm, stable surface.
214 - 2010 Standards: Titles II and III Department of Jus2ti5c1e
Titles II and III - 2010 Standards - 185