CHAPTER 8: SPECIAL ROOMS, SPACES, AND ELEMENTS TECHNICAL 810.2.2 Dimensions. Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches (1525 mm) minimum, measured parallel to the vehicle roadway. Figure 810.2.2 Dimensions of Bus Boarding and Alighting Areas 810.2.3 Connection. Bus stop boarding and alighting areas shall be connected to streets, sidewalks, or pedestrian paths by an accessible route complying with 402. 810.2.4 Slope. Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable. Perpendicular to the roadway, the slope of the bus stop boarding and alighting area shall not be steeper than1:48. 810.3 Bus Shelters. Bus shelters shall provide a minimum clear floor or ground space complying with 305 entirely within the shelter. Bus shelters shall be connected by an accessible route complying with 402 to a boarding and alighting area complying with 810.2. D2e5p2artment of Justice 2010 Standards: Titles II and III - 215 Titles II and III - 2010 Standards - 186

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.