TECHNICAL CHAPTER 10: RECREATION FACILITIES
1002.6.1 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be
provided in the load and unload area adjacent to the transfer device.
1002.6.2 Transfer Height. The height of transfer device seats shall be 14 inches (355 mm)
minimum and 24 inches (610 mm) maximum measured from the load and unload surface.
1002.6.3 Wheelchair Storage Space. Wheelchair storage spaces complying with 305 shall be
provided in or adjacent to unload areas for each required transfer device and shall not overlap any
required means of egress or accessible route.
1003 Recreational Boating Facilities
1003.1 General. Recreational boating facilities shall comply with 1003.
1003.2 Accessible Routes. Accessible routes serving recreational boating facilities, including
gangways and floating piers, shall comply with Chapter 4 except as modified by the exceptions in
1003.2.
1003.2.1 Boat Slips. Accessible routes serving boat slips shall be permitted to use the exceptions in
1003.2.1.
EXCEPTIONS: 1. Where an existing gangway or series of gangways is replaced or altered, an
increase in the length of the gangway shall not be required to comply with 1003.2 unless required
by 202.4.
2. Gangways shall not be required to comply with the maximum rise specified in 405.6.
3. Where the total length of a gangway or series of gangways serving as part of a required
accessible route is 80 feet (24 m) minimum, gangways shall not be required to comply with
405.2.
4. Where facilities contain fewer than 25 boat slips and the total length of the gangway or series
of gangways serving as part of a required accessible route is 30 feet (9145 mm) minimum,
gangways shall not be required to comply with 405.2.
5. Where gangways connect to transition plates, landings specified by 405.7 shall not be
required.
6. Where gangways and transition plates connect and are required to have handrails, handrail
extensions shall not be required. Where handrail extensions are provided on gangways or
transition plates, the handrail extensions shall not be required to be parallel with the ground or
floor surface.
7. The cross slope specified in 403.3 and 405.3 for gangways, transition plates, and floating
piers that are part of accessible routes shall be measured in the static position.
8. Changes in level complying with 303.3 and 303.4 shall be permitted on the surfaces of
gangways and boat launch ramps.