CHAPTER 10: RECREATION FACILITIES TECHNICAL
Advisory 1003.2.1 Boat Slips Exception 3. The following example shows how exception
3 would be applied: A gangway is provided to a floating pier which is required to be on an
accessible route. The vertical distance is 10 feet (3050 mm) between the elevation where
the gangway departs the landside connection and the elevation of the pier surface at the
lowest water level. Exception 3 permits the gangway to be 80 feet (24 m) long. Another
design solution would be to have two 40 foot (12 m) plus continuous gangways joined
together at a float, where the float (as the water level falls) will stop dropping at an elevation
five feet below the landside connection. The length of transition plates would not be
included in determining if the gangway(s) meet the requirements of the exception.
1003.2.2 Boarding Piers at Boat Launch Ramps. Accessible routes serving boarding piers at boat
launch ramps shall be permitted to use the exceptions in 1003.2.2.
EXCEPTIONS: 1. Accessible routes serving floating boarding piers shall be permitted to use
Exceptions 1, 2, 5, 6, 7 and 8 in 1003.2.1.
2. Where the total length of the gangway or series of gangways serving as part of a required
accessible route is 30 feet (9145 mm) minimum, gangways shall not be required to comply with
405.2.
3. Where the accessible route serving a floating boarding pier or skid pier is located within a boat
launch ramp, the portion of the accessible route located within the boat launch ramp shall not be
required to comply with 405.
1003.3 Clearances. Clearances at boat slips and on boarding piers at boat launch ramps shall comply
with 1003.3.
Advisory 1003.3 Clearances. Although the minimum width of the clear pier space is 60
inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to
improve the safety for persons with disabilities, particularly on floating piers.
1003.3.1 Boat Slip Clearance. Boat slips shall provide clear pier space 60 inches (1525 mm) wide
minimum and at least as long as the boat slips. Each 10 feet (3050 mm) maximum of linear pier
edge serving boat slips shall contain at least one continuous clear opening 60 inches (1525 mm)
wide minimum.
EXCEPTIONS: 1. Clear pier space shall be permitted to be 36 inches (915 mm) wide minimum
for a length of 24 inches (610 mm) maximum, provided that multiple 36 inch (915 mm) wide
segments are separated by segments that are 60 inches (1525 mm) wide minimum and 60
inches (1525 mm) long minimum.
2. Edge protection shall be permitted at the continuous clear openings, provided that it is 4
inches (100 mm) high maximum and 2 inches (51 mm) wide maximum.
3. In existing piers, clear pier space shall be permitted to be located perpendicular to the boat
slip and shall extend the width of the boat slip, where the facility has at least one boat slip
complying with 1003.3, and further compliance with 1003.3 would result in a reduction in the
number of boat slips available or result in a reduction of the widths of existing slips.
D2e6p6artment of Justice 2010 Standards: Titles II and III - 229
Titles II and III - 2010 Standards - 200
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.