CHAPTER 10: RECREATION FACILITIES TECHNICAL
EXCEPTIONS: 1. The clear width of accessible routes connecting elevated play
components shall be permitted to be reduced to 32 inches (815 mm) minimum for a distance
of 24 inches (610 mm) maximum provided that reduced width segments are separated by
segments that are 48 inches (1220 mm) long minimum and 36 inches (915 mm) wide
minimum.
2. The clear width of transfer systems connecting elevated play components shall be
permitted to be 24 inches (610 mm) minimum.
1008.2.5 Ramps. Within play areas, ramps connecting ground level play components and ramps
connecting elevated play components shall comply with 1008.2.5.
1008.2.5.1 Ground Level. Ramp runs connecting ground level play components shall have a
running slope not steeper than 1:16.
1008.2.5.2 Elevated. The rise for any ramp run connecting elevated play components shall be
12 inches (305 mm) maximum.
1008.2.5.3 Handrails. Where required on ramps serving play components, the handrails shall
comply with 505 except as modified by 1008.2.5.3.
EXCEPTIONS: 1. Handrails shall not be required on ramps located within ground level use
zones.
2. Handrail extensions shall not be required.
1008.2.5.3.1 Handrail Gripping Surfaces. Handrail gripping surfaces with a circular cross
section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39
mm) maximum. Where the shape of the gripping surface is non-circular, the handrail shall
provide an equivalent gripping surface.
1008.2.5.3.2 Handrail Height. The top of handrail gripping surfaces shall be 20 inches (510
mm) minimum and 28 inches (710 mm) maximum above the ramp surface.
1008.2.6 Ground Surfaces. Ground surfaces on accessible routes, clear floor or ground spaces,
and turning spaces shall comply with 1008.2.6.
Advisory 1008.2.6 Ground Surfaces. Ground surfaces must be inspected and maintained
regularly to ensure continued compliance with the ASTM F 1951 standard. The type of
surface material selected and play area use levels will determine the frequency of inspection
and maintenance activities.
1008.2.6.1 Accessibility. Ground surfaces shall comply with ASTM F 1951 (incorporated by
reference, see “Referenced Standards” in Chapter 1). Ground surfaces shall be inspected and
maintained regularly and frequently to ensure continued compliance with ASTM F 1951.
1008.2.6.2 Use Zones. Ground surfaces located within use zones shall comply with ASTM F
1292 (1999 edition or 2004 edition) (incorporated by reference, see “Referenced Standards” in
Chapter 1).