United States · ADA · Accessibility standard
2010 ADA Standards for Accessible Design
The Department of Justice’s scoping and technical accessibility requirements for facilities covered by the ADA.
- Publisher
- U.S. Department of Justice
- Edition
- 2010 standards
- Search coverage
- 279 of 279 PDF pages · 2 OCR pages
AccessibilityAnthropometry & ergonomics
Open original PDF at page 26 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
Subpart D of 28 CFR Part 36
(c) To the maximum extent feasible. The phrase “to the maximum extent feasible,” as
used in this section, applies to the occasional case where the nature of an existing
facility makes it virtually impossible to comply fully with applicable accessibility standards
through a planned alteration. In these circumstances, the alteration shall provide the
maximum physical accessibility feasible. Any altered features of the facility that can be
made accessible shall be made accessible. If providing accessibility in conformance
with this section to individuals with certain disabilities (e.g., those who use wheelchairs)
would not be feasible, the facility shall be made accessible to persons with other types of
disabilities (e.g., those who use crutches, those who have impaired vision or hearing, or
those who have other impairments).
§ 36.403 Alterations: Path of travel.
(a) General.
(1) An alteration that affects or could affect the usability of or access to an area of a
facility that contains a primary function shall be made so as to ensure that, to the
maximum extent feasible, the path of travel to the altered area and the restrooms,
telephones, and drinking fountains serving the altered area, are readily accessible to
and usable by individuals with disabilities, including individuals who use wheelchairs,
unless the cost and scope of such alterations is disproportionate to the cost of the
overall alteration.
(2) If a private entity has constructed or altered required elements of a path of travel
at a place of public accommodation or commercial facility in accordance with the
specifications in the 1991 Standards, the private entity is not required to retrofit such
elements to reflect the incremental changes in the 2010 Standards solely because of
an alteration to a primary function area served by that path of travel.
(b) Primary function. A “primary function” is a major activity for which the facility is
intended. Areas that contain a primary function include, but are not limited to, the
customer services lobby of a bank, the dining area of a cafeteria, the meeting rooms
in a conference center, as well as offices and other work areas in which the activities
of the public accommodation or other private entity using the facility are carried out.
Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker
rooms, janitorial closets, entrances, corridors, and restrooms are not areas containing a
primary function.
(c) Alterations to an area containing a primary function.
(1) Alterations that affect the usability of or access to an area containing a primary
22 - 2010 Standards: Title III Department of Justice
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.