AMERICANS WITH DISABILITIES ACT: SCOPING ADA CHAPTER 2: SCOPING REQUIREMENTS 205 Operable Parts 205.1 General. Operable parts on accessible elements, accessible routes, and in accessible rooms and spaces shall comply with 309. EXCEPTIONS: 1. Operable parts that are intended for use only by service or maintenance personnel shall not be required to comply with 309. 2. Electrical or communication receptacles serving a dedicated use shall not be required to comply with 309. 3. Where two or more outlets are provided in a kitchen above a length of counter top that is uninterrupted by a sink or appliance, one outlet shall not be required to comply with 309. 4. Floor electrical receptacles shall not be required to comply with 309. 5. HVAC diffusers shall not be required to comply with 309. 6. Except for light switches, where redundant controls are provided for a single element, one control in each space shall not be required to comply with 309. 7. Cleats and other boat securement devices shall not be required to comply with 309.3. 8. Exercise machines and exercise equipment shall not be required to comply with 309. Advisory 205.1 General. Controls covered by 205.1 include, but are not limited to, light switches, circuit breakers, duplexes and other convenience receptacles, environmental and appliance controls, plumbing fixture controls, and security and intercom systems. 206 Accessible Routes 206.1 General. Accessible routes shall be provided in accordance with 206 and shall comply with Chapter 4. 206.2 Where Required. Accessible routes shall be provided where required by 206.2. 206.2.1 Site Arrival Points. At least one accessible route shall be provided within the site from accessible parking spaces and accessible passenger loading zones; public streets and sidewalks; and public transportation stops to the accessible building or facility entrance they serve. EXCEPTIONS: 1. Where exceptions for alterations to qualified historic buildings or facilities are permitted by 202.5, no more than one accessible route from a site arrival point to an accessible entrance shall be required. 2. An accessible route shall not be required between site arrival points and the building or facility entrance if the only means of access between them is a vehicular way not providing pedestrian access. Advisory 206.2.1 Site Arrival Points. Each site arrival point must be connected by an accessible route to the accessible building entrance or entrances served. Where two or more similar site arrival points, such as bus stops, serve the same accessible entrance or entrances, both bus stops must be on accessible routes. In addition, the accessible routes must serve all of the accessible entrances on the site. Department of Justice 2010 Standards: Titles II and III - 2535 Titles II and III - 2010 Standards - 25

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.