ADA CHAPTER 2: SCOPING REQUIREMENTS AMERICANS WITH DISABILITIES ACT: SCOPING
Advisory 206.2.1 Site Arrival Points Exception 2. Access from site arrival points may
include vehicular ways. Where a vehicular way, or a portion of a vehicular way, is provided
for pedestrian travel, such as within a shopping center or shopping mall parking lot, this
exception does not apply.
206.2.2 Within a Site. At least one accessible route shall connect accessible buildings, accessible
facilities, accessible elements, and accessible spaces that are on the same site.
EXCEPTION: An accessible route shall not be required between accessible buildings,
accessible facilities, accessible elements, and accessible spaces if the only means of access
between them is a vehicular way not providing pedestrian access.
Advisory 206.2.2 Within a Site. An accessible route is required to connect to the boundary
of each area of sport activity. Examples of areas of sport activity include: soccer fields,
basketball courts, baseball fields, running tracks, skating rinks, and the area surrounding a
piece of gymnastic equipment. While the size of an area of sport activity may vary from
sport to sport, each includes only the space needed to play. Where multiple sports fields or
courts are provided, an accessible route is required to each field or area of sport activity.
206.2.3 Multi-Story Buildings and Facilities. At least one accessible route shall connect each
story and mezzanine in multi-story buildings and facilities.
EXCEPTIONS: 1. In private buildings or facilities that are less than three stories or that have
less than 3000 square feet (279 m2) per story, an accessible route shall not be required to
connect stories provided that the building or facility is not a shopping center, a shopping mall, the
professional office of a health care provider, a terminal, depot or other station used for specified
public transportation, an airport passenger terminal, or another type of facility as determined by
the Attorney General.
2. Where a two story public building or facility has one story with an occupant load of five or
fewer persons that does not contain public use space, that story shall not be required to be
connected to the story above or below.
3. In detention and correctional facilities, an accessible route shall not be required to connect
stories where cells with mobility features required to comply with 807.2, all common use areas
serving cells with mobility features required to comply with 807.2, and all public use areas are on
an accessible route.
4. In residential facilities, an accessible route shall not be required to connect stories where
residential dwelling units with mobility features required to comply with 809.2 through 809.4, all
common use areas serving residential dwelling units with mobility features required to comply
with 809.2 through 809.4, and public use areas serving residential dwelling units are on an
accessible route.
5. Within multi-story transient lodging guest rooms with mobility features required to comply with
806.2, an accessible route shall not be required to connect stories provided that spaces
complying with 806.2 are on an accessible route and sleeping accommodations for two persons
minimum are provided on a story served by an accessible route.
6. In air traffic control towers, an accessible route shall not be required to serve the cab and the
floor immediately below the cab.
5264 - 2010 Standards: Titles II and III Department of Justice
Titles II and III - 2010 Standards - 26