Analysis and Commenta ry o n the 2010 ADAStandards
This commenter’s interpretation and “comparable” vague and expressed concern
understanding are consistent with the about confusion the new requirement would
Department’s position in this matter. Section cause. This commenter suggested that the
215.4 of the 2010 Standards requires that phrase “equal area in square inches” be used
guest rooms required to have communication instead of comparable vanity space.
features be equipped with a fire alarm system
complying with section 702. Communication In some circumstances, the addition of
accessible guest rooms are required to a shelf in an existing facility may be a
have all of the communication features reasonable way to provide a space for
described in section 806.3 of the 2010 travelers with disabilities to use their toiletries
Standards including a fire alarm system and other personal items. However, this is a
which provides both audible and visible determination that must be made on a case-
alarms. The exception to section 215.1 of by-case basis. Comparable vanity countertop
the 2010 Standards, which applies only to space need not be one continuous surface
fire alarm requirements for guest rooms with and need not be exactly the same size as the
communication features in existing facilities, countertops in comparable guest bathrooms.
exempts the visible alarm requirement until For example, accessible shelving within
such time as the existing fire alarm system reach of the lavatory could be stacked to
is upgraded or replaced, or a new fire alarm provide usable surfaces for toiletries and
system is installed. If guest rooms in existing other personal items.
facilities are altered and they are required
by section 224 of the 2010 Standards to Shower and Sauna Doors in Transient
have communication features, such guest Lodging Facilities. Section 9.4 of the 1991
rooms are required by section 806.3 to have Standards and section 206.5.3 of the 2010
all other communication features including Standards both require passage doors in
notification devices. transient lodging guest rooms that do not
provide mobility features to provide at least
Vanity Counter Space. Section 806.2.4.1 32 inches of clear width. Congress directed
of the 2010 Standards requires that if vanity this requirement to be included so that
countertop space is provided in inaccessible individuals with disabilities could visit guests
transient lodging guest bathrooms, in other rooms. See H. Rept. 101-485, pt. 2,
comparable vanity space must be provided in at 118 (1990); S. Rept. 101-116, at 70 (1989).
accessible transient lodging guest bathrooms. Section 224.1.2 of the 2010 Standards adds
a new exception to clarify that shower and
A commenter questioned whether in sauna doors in such inaccessible guest
existing facilities vanity countertop space rooms are exempt from the requirement for
may be provided through the addition of a passage doors to provide at least 32 inches
shelf. Another commenter found the term of clear width. Two commenters requested