United States · ADA · Guidance
Guidance on the 2010 ADA Standards for Accessible Design
The Department of Justice’s explanation of changes to the ADA design standards, with section-by-section analysis and responses to public comments.
- Publisher
- U.S. Department of Justice
- Edition
- September 2010 guidance
- Search coverage
- 168 of 170 PDF pages · 4 OCR pages
AccessibilityAnthropometry & ergonomics
Open original PDF at page 129 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
Analysis and Com menta ry on the 201 0 A DAStandards
that saunas and steam rooms in existing of an accessible route. The 2010 Standards
facilities be exempt from the section 224.1.2 add a new scoping requirement that permits
requirement and that the requirement be platform lifts to be used to connect levels
made applicable to new construction only. within transient lodging guest rooms and
dwelling units with mobility features.
The exemption to the section 224.1.2
requirement for a 32-inch wide clearance 806 Transient Lodging Guest Rooms
at doors to shower and saunas applies
only to those showers and saunas in guest In the NPRM, the Department included floor
rooms which are not required to have plans showing examples of accessible guest
mobility features. Showers and saunas in rooms and bathrooms designs with mobility
other locations, including those in common features to illustrate how compliance with
use areas and guest rooms with mobility the 2010 Standards could be accomplished
features, are required to comply with the with little or no additional space compared to
32-inch clear width standard as well as designs that comply with the 1991 Standards.
other applicable accessibility standards.
Saunas come in a variety of types: portable, Commenters noted that the Department’s
pre-built, pre-cut, and custom-made. All plans showing accessible transient lodging
saunas except for custom-made saunas guest rooms compliant with the 2010
are made to manufacturers’ standard Standards were not common in the transient
dimensions. The Department is aware that lodging industry and also noted that the plans
creating the required 32-inch clearance omitted doors at sleeping room closets.
at existing narrower doorways may not
always be technically feasible. However, The Department agrees that the configuration
the Department believes that owners and of the accessible bathrooms is somewhat
operators will have an opportunity to provide different from past designs used by the
the required doorway clearance, unless industry, but this was done to meet the
doing so is technically infeasible, when an requirements of the 2010 Standards. The
alteration to an existing sauna is undertaken. plans were provided to show that, with some
Therefore, the Department has retained redesign, the 2010 Standards do not normally
these requirements. increase the square footage of an accessible
sleeping room or bathroom with mobility
Platform Lifts in Transient Lodging Guest features in new construction. The Department
Rooms and Dwelling Units. The 1991 has also modified several accessible guest
Standards, at section 4.1.3(5), exception 4, room plans to show that doors can be
and the 2010 Standards, at sections 206.7 installed on closets and comply with the 2010
and 206.7.6, both limit the locations where Standards.
platform lifts are permitted to be used as part
Department of Justice Guidance on the 2010 Standards: Titles II and III - 125