Analysis and Commenta ry o n the 2010 ADAStandards
The other issue in the comments represents exceptions covering operable parts intended
a misunderstanding of the Department’s only for use by service or maintenance
existing regulatory requirements. Employee personnel, electrical or communication
common use areas in covered facilities receptacles serving a dedicated use, and
(e.g., locker rooms, break rooms, cafeterias, floor electrical receptacles. Operable parts
toilet rooms, corridors to exits, and other covered by these new exceptions are exempt
common use spaces) were required to from all of the technical requirements for
be accessible under the 1991 Standards; operable parts in section 309. The 2010
areas in which employees actually perform Standards also add exceptions that exempt
their jobs are required to enable a person certain outlets at kitchen counters; heating,
using a wheelchair or mobility device to ventilating and air conditioning diffusers;
approach, enter, and exit the area. The 2010 redundant controls provided for a single
Standards require increased access through element, other than light switches; and
the accessible common use circulation path exercise machines and equipment from all
requirement, but neither the 1991 Standards of the technical requirements for operable
nor the 2010 Standards require employee parts. Exception 7, in section 205.1 of the
work stations to be accessible. Access to 2010 Standards, exempts cleats and other
specific employee work stations is governed boat securement devices from the accessible
by title I of the ADA. height requirement. Similarly, section
309.4 of the 2010 Standards exempts gas
205 and 309 Operable Parts pump nozzles, but only from the technical
requirement for activating force.
Section 4.1.3, and more specifically
sections 4.1.3(13), 4.27.3, and 4.27.4 of Reach Ranges. The 1991 Standards set
the 1991 Standards, require operable parts the maximum height for side reach at 54
on accessible elements, along accessible inches above the floor. The 2010 Standards,
routes, and in accessible rooms and spaces at section 308.3, lower that maximum height
to comply with the technical requirements to 48 inches above the finish floor or ground.
for operable parts, including height and The 2010 Standards also add exceptions, as
operation. The 1991 Standards, at section discussed above, to the scoping requirement
4.27.3, contain an exception, “ * * * where the for operable parts for certain elements that,
use of special equipment dictates otherwise among other things, will exempt them from
or where electrical and communications the reach range requirements in section 308.
systems receptacles are not normally
intended for use by building occupants,” from The 1991 Standards, at sections 4.1.3,
the technical requirement for the height of 4.27.3, and 4.2.6, and the 2010 Standards,
operable parts. Section 205.1 of the 2010 at sections 205.1, 228.1, 228.2, 308.3, and
Standards divides this exception into three 309.3, require operable parts of accessible
78 - Guidance on the 2010 Standards: Titles II and III Department of Justice