Bathing rooms: showers, tubs and transfer spaces

Accessible shower and bathtub layouts, transfer clearances, seats, grab bars and reachable controls.

AccessibilityAnthropometry & ergonomics
Open original PDF at page 14

Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.

Chapter 6: Plumbing Elements and Facilities Bathing Rooms Thresholds Thresholds are limited to a height of ½” and can be beveled, rounded, or vertical. No width is specified for the threshold. 14 xam ”2/1 Note: A threshold 2” high max. is permitted in alterations where providing a ½” threshold would disturb the structural reinforcement of the floor slab . This guide notes some provisions in the International Building Code (IBC) and the ICC A117.1 Standard for Accessible and Usable Buildings and Facilities that are not found in the ADA Standards. For example, the A117.1 standard, which provides technical provisions and is referenced by the IBC, requires a vertical grab bar at showers and bathtubs. It also requires a folding seat in all roll-in showers. Not all differences between the ADA Standards and editions of the IBC and A117.1 standard are noted in this guide.

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.