Chapter 6: Plumbing Elements and Facilities Bathing Rooms
Size and Clearance 60” min
The compartment size and the required
clearance adjacent to the open face of the
compartment permit maneuvering into the
shower with shower chairs or wheelchairs.
The clearance must abut, or be close to, the
shower entry but may be slightly forward of the
shower to accomodate tile edges or flanges
around the face of prefabricated showers.
60” min
Grab Bars
Grab bars are required on three walls in standard compartments
without a seat. Grab bars can be continuous or separate. If
separate, they must be 6” maximum from adjacent walls and
each must be at the same height above the finish floor. The
grab bars must extend across the side wall to the entry. A
maximum distance of the grab bar from the shower entry is not
specified, but they are to be installed near the entry.
5
nim
”03
nim
”03
Note: Dimensions measured to the center
point (vertical and horizontal) of opposing
walls.
A compliant lavatory can overlap one end
of the clearance but cannot be adjacent to
controls (or a folding seat).
”63
-
”33
6” max 6” max
48” min
Note: Grab bar to extend to shower entry
(distance from entry not specified)
xam
”6
xam
”6
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.