Entrances, doors and gates: approach clearances

Doorway clear widths, maneuvering spaces, thresholds and hardware, illustrated for different approach directions.

AccessibilityAnthropometry & ergonomicsStairs & circulation
Open original PDF at page 13

Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.

Chapter 4: Accessible Routes Entrances, Doors, and Gates Communication Access at Doors [§806.3.2, §809.5.5] In addition to requirements for two-way communication systems provided at restricted entrances, the Standards include requirements for communication access in transient lodging and residential facilities:  visible signals for door bells or knocks are required in transient lodging guest rooms providing communication access (§806.3.2);  a hard-wired doorbell with visible signals is required at the primary entrance in dwelling units providing communication access, along with a means to visually identify visitors without opening the door, such as a vision panel or peephole (§809.5.5). Recommendation: Peepholes and other means of identifying visitors in mobility accessible guest rooms and dwelling units are not addressed by the Standards. Products are available with prisms and optical lenses that do not require a close approach and can be easily used from standing and seated postures. They are more effective than locating a regular peephole at a lower height which can impact visual identification of visitors. Doors and Gates Operated Only By Security Personnel [§404.1, Ex] Manual doors, doorways, and gates that are designed to be operated only by security personnel, such as guards in a jail or prison, are exempt from requirements for hardware, closing speed, and opening force, but must meet all other requirements, including those for maneuvering clearance. This exception applies only where security personnel have sole control of doors or gates. If automated, such doors or gates are required to comply only with provisions for clear width and thresholds, as well as applicable provisions of the referenced ANSI/BHMA Standards. Automatic and Power-Assisted Doors and Gates [§404.3] Doors are not required to be automated, but must comply when provided. The Standards apply industry Standards developed under protocols of the American National Standards Institute (ANSI) and published by the Builders Hardware Manufacturers Association (BHMA). The ANSI/BHMA Standards address operating characteristics, including opening speed, safety features, sensors and activation devices, and labeling, among others. Doors are classified by their type or level of automation. 13

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.