United States · ADA · Illustrated standards guidance
Entrances, doors and gates: approach clearances
Doorway clear widths, maneuvering spaces, thresholds and hardware, illustrated for different approach directions.
- Publisher
- U.S. Access Board
- Edition
- Access Board guide to the 2010 ADA standards
- Search coverage
- 21 of 21 PDF pages
AccessibilityAnthropometry & ergonomicsStairs & circulation
Open original PDF at page 13 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
Chapter 4: Accessible Routes Entrances, Doors, and Gates
Communication Access at Doors [§806.3.2, §809.5.5]
In addition to requirements for two-way communication systems provided at restricted
entrances, the Standards include requirements for communication access in transient
lodging and residential facilities:
visible signals for door bells or knocks are required in transient
lodging guest rooms providing communication access (§806.3.2);
a hard-wired doorbell with visible signals is required at the primary
entrance in dwelling units providing communication access, along
with a means to visually identify visitors without opening the door,
such as a vision panel or peephole (§809.5.5).
Recommendation: Peepholes and other means of identifying visitors in mobility
accessible guest rooms and dwelling units are not addressed by the Standards.
Products are available with prisms and optical lenses that do not require a close
approach and can be easily used from standing and seated postures. They are
more effective than locating a regular peephole at a lower height which can
impact visual identification of visitors.
Doors and Gates Operated Only By Security Personnel [§404.1, Ex]
Manual doors, doorways, and gates that are designed to be operated
only by security personnel, such as guards in a jail or prison, are exempt
from requirements for hardware, closing speed, and opening force, but
must meet all other requirements, including those for maneuvering
clearance. This exception applies only where security personnel have
sole control of doors or gates. If automated, such doors or gates are
required to comply only with provisions for clear width and thresholds, as
well as applicable provisions of the referenced ANSI/BHMA Standards.
Automatic and Power-Assisted Doors and Gates [§404.3]
Doors are not required to be automated, but must comply when
provided. The Standards apply industry Standards developed under
protocols of the American National Standards Institute (ANSI) and
published by the Builders Hardware Manufacturers Association
(BHMA). The ANSI/BHMA Standards address operating
characteristics, including opening speed, safety features, sensors and
activation devices, and labeling, among others. Doors are classified
by their type or level of automation.
13
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.