Table C1 Continued
Proposed works Target Typical construction Comments (reasonableness, practicability
U-value and cost-effectiveness)
W/(m2·K)
Ground floor constructions
Renovation of a solid or See Solid floor – replace The cost-effectiveness of floor insulation
suspended floor involving the comment screed with an is complicated by the impact of the size
replacement of screed or a insulated floor deck and shape of the floor (ratio of perimeter
timber floor deck to maintain existing to area). In many cases, existing uninsulated
floor level floor U-values are already relatively low
when compared with wall and roof U-values.
Suspended timber
Where the existing floor U-value is greater
floor – fit insulation
than 0.70W/(m2·K), added insulation is likely
between floor joists
to be cost-effective. Analysis shows that
before replacing
the cost–benefit curve for the thickness of
floor deck
added insulation is flat; therefore, a target
U-value of 0.25W/(m2·K) is appropriate,
subject to other technical constraints
(adjoining floor levels, etc.)