Skip to content

United States · ADA · Guidance

Guidance on the 2010 ADA Standards for Accessible Design

The Department of Justice’s explanation of changes to the ADA design standards, with section-by-section analysis and responses to public comments.

AccessibilityAnthropometry & ergonomics
Open original PDF at page 102

Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.

Com pa rison of Single-User Toilet Room Layouts 2010 Standards Plan-1C: 2010 Standards Minimum with Out-Swinging Door (entry door has both closer and latch) 7’-0” x 5’-6” • 38.50 Square Feet This plan shows the same typical features of a single- user toilet room that meets the minimum requirements of the 2010 Standards as Plan-1B does except the entry door has both a closer and latch. Because the door has both a closer and latch, a minimum additional foot of maneuvering space is required on the latch side (see section 404.2.4.1 and Figure 404.2.4.1(c) of the 2010 Standards). This layout is six point two percent (6.2%) larger than the accompanying Plan-1A: 1991 Standards Minimum with Out-Swinging Door example. 98 - Guidance on the 2010 Standards: Titles II and III DDeeppaarrttmmeenntt ooff JJuussttiiccee

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.